Hampton Natrix • Natrix 2 • Natrix HT

Hampton Natrix • Natrix 2 • Natrix HT

Applications

  Primary biased sparse matrix crystallization screen for nucleic acids & protein/nucleic acid complexes  主要用于核酸和蛋白质/核酸复合物的删选

Features

Nucleic acid sparse matrix screen
Sparse matrix formulation efficiently samples salts, polyols, polymers, organics, additives & pH
pH range 5.6 – 8.5
Tube or Deep Well block format
 Description
Natrix, Natrix 2 and Natrix HT are based upon published reagent formulations for the crystallization of nucleic acids and protein-nucleic acid complexes. A variety of hammerhead ribozymes and other ribozymes, RNAs, DNAs, RNA-drug complexes, and RNA-protein complexes have been crystallized using the Natrix protocols.By using sparse matrix sampling technology, The Natrix kits allow one to quickly test wide ranges of pH, salts, and precipitants using a very small sample of nucleic acid.

Natrix screens are unique in that rather than relying solely on the traditional nucleic acid precipitant MPD, Natrix screens also utilize Polyethylene glycols (PEGs) in a variety of molecular weights (200, 400, 4,000, 8,000) as well as 2-Propanol, Polyethylene glycol monomethyl ether (PEG MME), and 1,6-Hexanediol. Many of the polymeric and low molecular weight organic precipitants are combined with various monovalent salts as precipitating agents. This combination of salts and low molecular weight organics and polyalcohols, as well as the utilization of varying chain length PEGs, has proven to be a successful combination for producing nucleic acid and protein-nucleic acid complex crystals.

Natrix contains 48 unique reagents, 10 ml each and is based on the sparse matrix formulation first described by William Scott in 1995.

Natrix 2, an extension of Natrix, contains 48 unique reagents, 10 ml each. Natrix 2 is a biased sparse matrix screen based on extracting patterns from crystallization data as well as reagent formulations first described by Berger et al in 1996.

Natrix HT contains 1 ml of each reagent from Natrix and Natrix 2 in a single Deep Well block format.

Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

Natrix • Natrix 2 • Natrix HT
Natrix • Natrix 2 • Natrix HT
View Full Size
Natrix • Natrix 2 • Natrix HT

 

CAT NO NAME DESCRIPTION
HR2-116 Natrix 10 ml, tube format
HR2-117 Natrix 2 10 ml, tube format
HR2-131 Natrix HT 1 ml, Deep Well block format

Hampton 蛋白结晶删选试剂– Index HT

Hampton 蛋白结晶删选试剂– Index HT

Applications

Primary, diverse reagent system crystallization screen for proteins, complexes, peptides, nucleic acids, & water soluble small molecules

多样结晶试剂系统删选试剂盒,用于蛋白质,复合物,肽,核酸,和水溶性的小分子。

Features

 Developed at Hampton Research

Screens classic, contemporary, & modern crystallization reagents

Samples pH 3 to 9

Compatible with microbatch, vapor diffusion, & liquid diffusion methods

Specially formulated reagent zones:

1 .Traditional salts versus pH

2.Neutralized organic acids

3.High [salt] with low [polymer]

4.High [polymer] with low [salt]

5.Low ionic strength versus pH

6.PEG & Salt versus pH

7.PEG & Salt

 Tube or Deep Well block format

Description
Index is designed as a 96 reagent crystallization screen that combines the strategies of the grid, sparse matrix, and incomplete factorial screening with traditional, contemporary, and new crystallization reagent systems into a highly effective and efficient format.

Index, as the name implies, efficiently samples a series of specially formulated reagent zones to identify which reagent class or classes and pH are effective in producing crystals or limiting sample solubility. Results from Index can be used to design optimization experiments and to identify follow on screens by reagent class. For example, positive results with salt based reagents in Index may be followed up with further screening using SaltRx or Grid Screen Salt HT. Success with polymer based reagents in Index may be followed up with further screening using PEGRx or PEG/Ion.

Index utilizes a broad, yet refined portfolio of crystallization reagent systems. These include the following: (1) traditional salts such as Ammonium sulfate and Sodium chloride versus pH; (2) neutralized organic acids such as Sodium malonate and Tacsimate; (3) High salt concentration mixed with low polymer concentration as well as high polymer concentration mixed with low salt concentration and; (4) Low ionic strength using polymers such as PEG, MPD, Pentaerythritols versus pH. These reagent systems are formulated across a sparse matrix and incomplete factorial of concentration ranges, sampling a pH range of 3 to 9.

Index contains 96 unique reagents, 10 ml each.

Index HT contains 96 unique reagents in a single Deep Well block format.

Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.

Measured pH range of kit is 3 to 9 at 25°C
Average measured pH of kit is 6.8 at 25°C
Median measured pH of kit is 6.9 at 25°C

Index • Index HT

Index • Index HT

Apo Kinase crystal. Initial hit from the Hampton Research Index Screen. Annie Hassell, Glaxo Smithkline.

Index • Index HT

Crystal of a heme-based sensor from Thermoanaerobacter Tengcongensis grown using the Hampton Research Index screen. Patricia Pellicena & John Kuriyan at University of California, Berkeley, USA.

CAT NO NAME DESCRIPTION
HR2-144 Index 10 ml, tube format
HR2-134 Index HT 1 ml, Deep Well block format

Hampton蛋白质结晶捞针(结晶环)18 mm Mounted CryoLoop™

Hampton蛋白质结晶捞针(结晶环)18 mm Mounted CryoLoop™

Applications

Cryocrystallography

Features

Adjustable loop orientation
Synthetic CryoLoop on adjustable stainless steel MicroTube
MicroTube specially engineered with EasySnap notches
20 micron diameter nylon CryoLoop

Description
Similar to the Mounted CryoLoop™ in design and function, the Adjustable Mounted CryoLoop allows one to manipulate and orient the CryoLoop to multiple, unique positions previously unattainable with typical cryo setups. The Adjustable Mounted CryoLoop is a 20 micron diameter synthetic loop mounted inside a malleable stainless steel sleeve, which in turn, is mounted inside the EasySnap MicroTube™.

Using a specially designed L-shaped tool (HR5-902) with a positioning notch, one can manipulate the angle and orientation of the CryoLoop by bending and adjusting the angle of the malleable stainless steel insert which holds the CryoLoop. The Adjustable Mounted CryoLoop may be positioned several times. Note: Repeated manipulation will fatigue the sleeve which can lead to failure of the sleeve. The Adjustable Mounted CryoLoop is designed to work with the CrystalCap System components.

The MicroTube is 24 mm in length and is specially engineered with EasySnap™ notches at the 10, 12, 14, 18, and 21 mm measures. To obtain the desired length of MicroTube, simply snap the MicroTube at the desired length and stake it to the CrystalCap™ Magnetic or CrystalCap™ Copper Magnetic. These nylon loops show minimal diffraction, are thin for fast freezing, strong, and aerodynamic.

Most data collection geometries prefer or require a 22 mm length between the base of the cap and the beam. For a 22 mm overall length using the CrystalCap, CrystalCap ALS, CrystalCap ALS HT and CrystalCap SPINE HT, snap the MicroTube at the second notch from the bottom, creating an 18 mm MicrozTube lenghth and secure to the CrystalCap using epoxy or similar adhesive. For a 22 mm over length using the CrystalCap Copper, CrystalCap Copper HT, CrystalCap ALS Copper HT snap the MicroTube at the fifth notch from the bottom (notch closest to the CryoLoop) and secure to the CrystalCap using epoxy or similar adhesive.

The HR5-902 Tool for Adjustable Mounted CryoLoop is not included with the Adjustable Mounted CryoLoop and must be purchased as a separated item.

18 mm Mounted CryoLoop™ - 20 micron

18 mm Mounted CryoLoop

18 mm Mounted CryoLoop™ - 20 micron

18 mm Mounted CryoLoop properly installed in a CrystalCap Magnetic

18 mm Mounted CryoLoop™ - 20 micron

Crystal in CryoLoop

CAT NO NAME DESCRIPTION
HR4-932 18 mm Mounted CryoLoop – 20 micron 0.025 – 0.05 mm – 25 pack
HR4-945 18 mm Mounted CryoLoop – 20 micron 0.05 – 0.1 mm – 25 pack
HR4-947 18 mm Mounted CryoLoop – 20 micron 0.1 – 0.2 mm – 25 pack
HR4-970 18 mm Mounted CryoLoop – 20 micron 0.2 – 0.3 mm – 25 pack
HR4-971 18 mm Mounted CryoLoop – 20 micron 0.3 – 0.4 mm – 25 pack
HR4-972 18 mm Mounted CryoLoop – 20 micron 0.4 – 0.5 mm – 25 pack
HR4-973 18 mm Mounted CryoLoop – 20 micron 0.5 – 0.7 mm – 25 pack
HR4-974 18 mm Mounted CryoLoop – 20 micron 0.7 – 1.0 mm – 25 pack
HR4-918 18 mm Mounted CryoLoop – 20 micron Sampler – 30 pack (5 of each diameter size 0.1 – 1.0 mm)

Hampton 银弹 Silver Bullets

Hampton 银弹 Silver Bullets

Applications

Additive screen for the optimization of protein crystals
For use with soluble proteins and membrane proteins
Additive screen to discover different crystal forms
Secondary or orthogonal crystallization screen when traditional screens are not successful
Additive screen for the optimization of protein solubility and stability

Features

Developed at Hampton Research
Screens a portfolio of small molecules and excipients for their ability to establish stabilizing, intermolecular, hydrogen bonding, hydrophobic and electrostatic interactions which could promote lattice formation and crystallization

Small organic acids & organic salts
Biologically active small molecules
Amino acids & peptides
Macromolecular digests
Co-factors & ligands
Biochemical pathway intermediates
Nucleotides, pharmacaphores & carbohydrates

Description
Silver Bullets screens a portfolio of small molecules for their ability to establish stabilizing, inter molecular, hydrogen bonding, hydrophobic and electrostatic interactions which could promote stability, lattice formation, and crystallization.1-3

Published results with the Silver Bullets have been very encouraging, with more than twice as many proteins being crystallized overall as were crystallized from controls free of any small molecules.1-3

X-ray diffraction analysis has revealed the small molecule Silver Bullets in the crystal lattice, involved at the centers of hydrogen bonding networks and electrostatic interaction.1-3 Silver Bullets is compatible with hanging, sitting and sandwich drop vapor diffusion, microbatch, free interface, and microdialysis crystallization methods. Silver Bullets can be used with Dynamic Light Scattering (DLS), ThermoFluor, and Size Exclusion Chromatography assays.

Silver Bullets reagent portfolio
•Organic salts and acids
•Biologically active small molecules
•Amino acids and peptides
•Macromolecular digests

The Silver Bullets kit is a library of small molecules that have been shown to promote crystal lattice formation. X-ray diffraction analysis has demonstrated the reagents have the ability to:

•Stabilize the conformation of the protein
•Perturb the interaction of the protein with the solvent
•Participate in forming important lattice contacts
•Build the crystal lattice by forming reversible cross-links between the macromolecules in the crystal

The Silver Bullets kit is composed of 96 solutions in a single Deep Well block (Greiner 786261 block specifications: Total Volume: 0.5 mL Working Volume: 0.03 – 0.7 mL at Room Temperature 0.03 – 0.55 mL at -20ºC, Well Profile: Conical (V), Bottom Well Bottom: Solid, Plate Color: Translucent), HT format.

Each Silver Bullets reagent is a mixture of small molecules or macromolecular digests in 0.02 M HEPES sodium pH 6.8 buffer. Each solution contains between 2 and 20 small molecules.

Silver Bullets reagent volume is 0.5 ml (each well).

ThermoFluor is a registered trademark of Johnson & Johnson.

Hampton  Silver Bullets Bio

Silver Bullets • Silver Bullets Bio

Silver Bullets • Silver Bullets Bio

上海金畔生物作为Hampton蛋白结晶产品的代理商,竭诚为您服务,欢迎新老客户咨询。

Applications 应用

Additive screen for the optimization of protein crystals
For use with soluble proteins and membrane proteins
Additive screen to discover different crystal forms
Secondary or orthogonal crystallization screen when traditional screens are not successful
Additive screen for the optimization of protein solubility and stability

Features

Screens a portfolio of small molecules and excipients for their ability to establish stabilizing, intermolecular, hydrogen bonding, hydrophobic and electrostatic interactions which could promote lattice formation and crystallization

Small organic acids & organic salts
Biologically active small molecules
Amino acids & peptides
Macromolecular digests
Co-factors & ligands
Biochemical pathway intermediates
Nucleotides, pharmacaphores & carbohydrates

 

Developed at Hampton Research
Two sets of 96 reagents, composed of more than 1,090 chemicals, of which more than 400 are uniqu

Please note, the Silver Bullets Bio Screen is temporarily unavailable as a new formulation is in development

 

Hampton50号毛细管Glass Number 50 Capillaries

Hampton50号毛细管Glass Number 50 Capillaries

Glass Number 50 Capillaries

应用:

  X-ray data collection

  Liquid-liquid diffusion crystallization

  Gel acupuncture crystallization

Features

  Glass Number 50 (borosilicate)

  Thin walled – 10 micron

      上海金畔生物作为Hampton蛋白结晶产品的代理商,竭诚为您服务,欢迎新老客户咨询。

Description 描述
Glass Number 50 (borosilicate glass) capillaries that are extremely thin walled (approximately 10 micron wall thickness). The length of the capillary has a well defined diameter, with one end having a funnel shape and the other end closed. Glass capillaries have a wall thickness of 0.01 mm and an overall length of 80 mm +/- 5 mm. Glass capillaries are available in a wide range of outside diameters from 0.1 mm to 2.0 mm. They are designed to mount, hold, and store small molecule and biological macromolecular crystals for x-ray data collection. Capillaries can also be used for crystal density measurements and crystal growth experiments. The capillaries can be sealed tightly against moisture and gases using wax, epoxy, or other sealing materials.

In determining what glass or quartz capillary is right for you, please refer to the “Linear Absorption Coefficient µ cm-1” table. This table indicates the amount of radiation that is absorbed by the capillary during x-ray data collection.

For 0.1 mm to 2.0 mm capillaries the open end capillary tube base size is 3.0 +/- 0.15 mm OD x 0.13 +/- 0.10 mm Wall thickness.

The Diameter is measured 40 mm from the closed end. The tolerances are as follows

Glass Number 50 Capillaries

Glass Number 50 Capillaries

 

0.1 mm -0.075 / +0.075 mm
0.2 mm -0.050 / +0.050 mm
0.3 mm -0.050 / +0.100 mm
0.4 mm -0.100 / +0.100 mm
0.5 mm -0.100 / +0.100 mm
0.6 mm -0.100 / +0.100 mm
0.7 mm -0.150 / +0.150 mm
0.8 mm -0.150 / +0.150 mm
0.9 mm -0.150 / +0.150 mm
1.0 mm -0.150 / +0.250 mm
1.5 mm -0.250 / +0.250 mm
2.0 mm -0.250 / +0.250 mm

Capillaries have only been tested at atmospheric pressure (760 mmHg (torr), 29.92 inHg, 14.696 psi). Use at other pressures has not been tested.

Sigma代理  Abcam代理  CST代理  Santa Cruz代理  Biolegend代理 ebioscience代理  Invitrogen代理   millipore代理  BD流式抗体代理   GeneTe x抗体代理  Novus抗体代理   R&D代理 Biovison代理  Jackson代理  MBL抗体代理  ProSpec抗体代理  Bethyl抗体代理  Antibody Revolution抗体代理  Torrey Pines Biolabs代理  Amresco代理  MPbio代理  Laysan bio代理  NANOCS代理  Avanti代理  wako代理  lumiprobe代理(活性荧光染料)   NEB酶代理  Roche酶代理  Toyobo酶代理   USP代理  EP代理  Dr代理  TRC代理  TCI代理  Reagecon代理 Megazyme代理 Hampton代理(蛋白结晶) whatman代理(滤膜滤纸) GE代理(蛋白纯化) Corning康宁代理  Axygen代理 Falcon代理  NISSUI日水代理 Himedia代理 OXOID代理  BD培养基代理 Ludger代理(糖蛋白分析产品)  Eppendorf代理  Labnet代理  标准品代理 抗体代理 酶试剂代理  培养基代理 耗材代理 Elisa试剂盒代理 。